I. Verifica dell'accuratezza di base
1. Repeatability Test: Measure 20 times consecutively using a standard part. The repeatability accuracy should be ≤0.8μm (≤0.3μm for high-precision models). If the standard deviation is >1,2μm, è necessaria la calibrazione.
2. Systematic Error Detection: Measure standard parts of different sizes (e.g., 10mm, 50mm, 100mm). If the deviation is consistently >±2,5μm, è necessaria la compensazione.
3. Verifica della precisione geometrica:
Guide rail straightness: Error per meter >2μm
Worktable flatness: Full stroke error >3μm
Three-axis perpendicularity: Angular error >5 secondi d'arco.
II. Valutazione del sistema di sonda
Calibration ball diameter consistency: If the measurement difference in different directions by the same probe is >0.8μm or the roundness error is >0,5μm, è necessaria la ricalibrazione.
Multi-probe consistency: If the deviation of each probe measuring the same dimension is >2μm, la relazione della sonda necessita di calibrazione.
III. Ispezione della temperatura e della manutenzione
Stabilità della temperatura: variazioni della temperatura ambiente > ±0,5 gradi possono influire sulla precisione.
Manutenzione giornaliera: pulire regolarmente e ispezionare i fori di posizionamento per eventuali segni di usura (come aumento di dimensioni o deformazione); nei casi più gravi è necessaria la riparazione o la sostituzione.